General Specifications for Equipment FAT Acceptance
All components of the entire machine must be fully and completely installed. The inner and outer surfaces must be uniformly polished, smooth and flat, easy to clean, free from loose particles, incapable of harboring contaminants, and non-contaminating to pharmaceutical products. There shall be no burrs, rust, scratches, or unevenness; weld seams must be smooth and even, with no visible weld spots or dark scars. The painted surfaces must be intact, uniform, and glossy, free from discoloration, dripping, or flaking. The installed doors must be neat and aesthetically pleasing, without any deformation, and operate smoothly and flexibly. This includes silicone gaskets around the control box doors, ensuring that there are no weld points inside the box and no burrs around the edges. The entire machine must be thoroughly cleaned and maintain a bright, pristine appearance.